8–10 mins Rapid Readout Time | 0.5 µg/kg Strict Trace LOD (0.5 ppb) | 10 Tests Complete Kit Pack | 12 Months Shelf Life (4–30°C) |
The FSTest Clenbuterol Rapid Test Kit is a highly efficient on-site screening tool developed for the rapid qualitative detection of clenbuterol residues in livestock muscle tissues.
Clenbuterol is a beta-agonist additive strictly banned or regulated globally due to severe public health risks. This kit empowers meat wholesalers, slaughterhouses, food processors, and inspectors to perform immediate safety checks, delivering clear visual results within 8 to 10 minutes without the immediate necessity for complex laboratory instrumentation like LC-MS/MS.
Ultra-High Sensitivity (0.5 µg/kg LOD): Features an exceptional Limit of Detection of 0.5 µg/kg (0.5 ppb), ensuring that trace veterinary chemical residues are effectively captured.
Rapid Field Mobility: Eradicates the immediate need for heavy and costly laboratory instrumentation during initial sorting, enabling testing on processing floors or receiving docks.
Chemical Trace Accuracy: Designed to target the exact chemical signature of Clenbuterol (CAS No. 37148-27-9, MW: 277.19 g/mol).
Definite Visual Interpretation: Utilizes a competitive lateral flow immunochromatographic format where an increasing concentration causes the Test (T) line to fade, eliminating subjective reading errors.
Convenient Ambient Storage: Unopened kits can be kept safely sealed at 4–30°C in a cool, dry place for up to 12 months.
| Product Name | Clenbuterol Rapid Test Kit |
|---|---|
| Catalog Number | 26102 |
| Target Analyte Compound | Clenbuterol (CAS: 37148-27-9 | MW: 277.19 g/mol) |
| Detection Principle | Competitive Lateral Flow Immunochromatography (Colloidal Gold) |
| Pack Size | 10 tests / kit |
| Assay Run Time & Volume | 8–10 minutes (results invalid after 10 minutes); 100 µL test supernatant |
| Storage & Shelf Life | 12 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Target Analyte Compound | CAS Registry Number | Limit of Detection (LOD) |
|---|---|---|
| Clenbuterol (Beta-Agonist Residue) | 37148-27-9 | 0.5 µg/kg (0.5 ppb) |
Optimized for testing veterinary beta-agonist residues across livestock muscle matrices:
STEP 1 Extraction Weigh 4 g homogenized muscle tissue (fat-free) into a 15 mL tube, add 0.5 mL Extracting Solution, and vortex or shake thoroughly for 2 minutes. | STEP 2 Heat & Centrifugation Place tube in an 80°C water bath for 10 min. Centrifuge at 4000 rpm for 5 min, then cool supernatant back down to room temperature. | STEP 3 Microwell Reaction Ensure 20–40°C environment. Pipette 100 µL cooled supernatant into microwell, mix 3–5 times with pipette, and let stand for 5 minutes. | STEP 4 Load & Read (8–10 Mins) Transfer all mixed solution into cassette sample hole. Interpret visual lines strictly at 8–10 minutes. Results are completely invalid after 10 minutes. |
Negative (-): The Test (T) line develops a strong, clear color equal to or darker than the Control (C) line → Clenbuterol levels are absent or below 0.5 µg/kg.
Positive (+): The Test (T) line is visibly lighter than the Control (C) line or completely invisible → Clenbuterol residue is present at or above 0.5 µg/kg.
Invalid: The Control (C) line fails to develop after the sample is applied, regardless of the T line color. Repeat with a new strip.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Sample Integrity: Ensure the homogenized meat sample consists only of muscle tissue; fat and skin must be strictly avoided during preparation to protect result accuracy.
Water Bath Caution: Ensure the 80°C water bath level surpasses the liquid inside the centrifuge tube, and verify tubes are sealed tightly to prevent water leaks.
Operator Safety: The extracting solution is corrosive and irritating. Protective gloves must be worn throughout the experiment, and waste materials must be disposed of as hazardous chemical waste.
Strict Time Window: Read visual test results strictly between 8–10 minutes after loading cassette; results observed after 10 minutes are invalid.
Kit Components Included: 10 Test Cassettes, Microwells, 1 bottle of Clenbuterol Extracting Solution, 10 Centrifuge Tubes (15 mL), User Manual.
Required Equipment (Not Provided): Analytical balance, vortexer/shaker, 80°C water bath, centrifuge (≥ 4000 rpm), micropipette (100 µL) & tips, timer, and protective PPE gear.